Pacemaker, ICD & CRT Implantation

Pacemaker & ICD
KG Heart Center — Electrophysiology & Cardiac Devices, Coimbatore

Pacemaker & ICD Implantation in Coimbatore —
The Full Range of
Heart Rhythm Devices

A pacemaker keeps a slow heart beating at a safe rate; an ICD watches for dangerous fast rhythms and corrects them with pacing or a shock; and CRT helps a weak heart pump in step. At KG Hospital, Coimbatore, electrophysiologists implant all three — including leadless and conduction system pacing — under local anaesthesia, usually as a day case or overnight stay.

Devices at KGH full range
1
Single & Dual-Chamber Pacemakers
Standard support for a slow heartbeat
2
Leadless Pacemaker
No leads, no chest pocket
3
Conduction System Pacing
HIS bundle & left bundle branch area pacing
4
CRT for Heart Failure
Helps both sides of the heart beat together
★
ICD — Sudden Death Prevention
Treats life-threatening fast rhythms
Anaesthesia
LocalYou stay awake and comfortable
Stay
Day caseOr one night for most implants
Follow-up
RemoteDevice monitoring from home
Since
1974NABH-accredited heart care

What Is a Pacemaker,
and How Is an ICD Different?

Quick answer

A pacemaker is a small battery-powered device, placed under the skin below the collarbone, that sends tiny electrical pulses to the heart when it beats too slowly. An ICD (implantable cardioverter-defibrillator) looks similar but also detects life-threatening fast heart rhythms and stops them with rapid pacing or an electric shock. Every ICD can also work as a pacemaker.

Your heartbeat is controlled by an electrical system. When that system slows down or is blocked — for example in heart block or sick sinus syndrome — the heart may beat too slowly to pump enough blood, causing dizziness, fainting or tiredness. A pacemaker fills in the missing beats.

Some people are at risk of the opposite problem: very fast, chaotic rhythms from the lower chambers (ventricular tachycardia or fibrillation) that can stop the heart pumping within seconds. An ICD monitors every heartbeat and treats these rhythms automatically, which is why it is called a life-saving device for sudden cardiac arrest.

At KG Heart Center, devices are implanted by the cardiology and electrophysiology team, who also programme and follow up every device after implantation.

KG Heart Center cardiology and electrophysiology team, KG Hospital Coimbatore
  • Local anaesthesia
  • Small cut below collarbone
  • Usually about 1–2 hours
  • Day case or overnight
  • Leadless option available
  • Remote monitoring

When Is a Pacemaker
or ICD Needed?

DizzinessLight-headedness or feeling faint
Fainting (syncope)Sudden blackouts, sometimes without warning
Slow pulseOften below 40–50 beats per minute
TirednessLow energy and poor exercise tolerance
BreathlessnessOn mild exertion
PalpitationsRacing or irregular heartbeat
✓  A pacemaker is usually advised for
Complete or advanced heart block
Sick sinus syndrome with symptoms
Slow heart rate with fainting or dizziness
Atrial fibrillation with a very slow pulse
Heart block after a TAVI or heart surgery
✓  An ICD or CRT may be advised for
Survivors of cardiac arrest
Ventricular tachycardia or fibrillation
A weak heart (low ejection fraction) despite treatment
Heart failure with a wide QRS on ECG (CRT)
Some inherited conditions with high sudden-death risk

Decisions follow international guidelines (ESC 2021 on cardiac pacing and CRT; ESC 2022 on ventricular arrhythmias). If your rhythm problem can be cured by catheter ablation instead of a device, your electrophysiologist will discuss that too.

Types of Pacemakers
& Cardiac Devices at KGH

01

Single & Dual-Chamber Pacemaker

One lead (single-chamber) or two leads (dual-chamber, in the upper and lower chambers) connected to a small generator under the skin. Dual-chamber pacing keeps the natural timing between the chambers.

Standard
02

Leadless Pacemaker

A capsule-sized pacemaker placed directly inside the heart through a vein in the groin. There are no leads and no chest pocket, which lowers the risk of lead and pocket problems.

No leads
03

Conduction System Pacing

HIS bundle pacing and left bundle branch area pacing stimulate the heart’s own wiring, so the heart contracts in a more natural pattern than with conventional right ventricular pacing.

Physiological
04

CRT — Cardiac Resynchronisation

A three-lead device (CRT-P, or CRT-D with a defibrillator) that coordinates both lower chambers in heart failure. CRT improves symptoms in about 60–70% of suitable heart-failure patients.

Heart failure
06

Battery Replacement & Upgrades

When a battery runs low, the generator is replaced in a short procedure, usually reusing the existing leads. Devices can also be upgraded, for example from a pacemaker to CRT.

Follow-up

Tests Before a
Pacemaker or ICD

The goal of testing is to link your symptoms to a definite rhythm problem and to check how well your heart pumps — because that decides whether you need a pacemaker, an ICD, CRT or a different treatment.

Some patients need an electrophysiology study (EPS), in which thin catheters map the heart’s electrical system from the inside. It is performed in KG Hospital’s cath lab, and if a treatable short-circuit is found, ablation can sometimes be done in the same sitting.

Typical evaluation
ECGHeart rate, rhythm and conduction
Holter monitor24–48 hour rhythm recording
EchocardiogramPumping strength (ejection fraction)
Treadmill testHeart rate response to exercise
EP studyMaps the electrical system, if needed

Pacemaker Implantation —
Step by Step

Preparation

You may be asked to fast for a few hours and to adjust blood thinners. An antibiotic is given to prevent infection. The procedure is done in the cath lab.

Local anaesthesia

The area below the collarbone is numbed; you stay awake, with light sedation if needed. A small cut of about 5 cm is made.

Placing the leads

Under X-ray guidance, one to three thin leads are passed through a vein into the heart and tested to make sure they sense and pace correctly. For a leadless pacemaker, the device is placed through a vein in the groin instead.

Connecting the device

The leads are connected to the generator, which sits in a small pocket under the skin. The wound is closed, usually with dissolvable stitches.

Checks and discharge

The device is programmed and checked, along with an X-ray. Most patients go home the same day or the next day with a device ID card and a follow-up date.

Pacemaker vs ICD vs CRT
at a Glance

Comparison of pacemaker, ICD and CRT devices
Factor Pacemaker ICD CRT
Main purposeTreats a slow heartbeatStops dangerous fast rhythmsMakes both ventricles beat together
Typical patientHeart block, sick sinusCardiac arrest survivor, weak heartHeart failure with wide QRS
Delivers a shock?NoYes, when neededOnly CRT-D
Leads0 (leadless) to 21–23
Hospital stayDay case or 1 nightUsually 1 night1–2 nights

Typical figures; your stay depends on your device and overall health. Many CRT and ICD patients are followed in KG Hospital’s Advanced Heart Failure Clinic.

Recovery & Living
With a Device

Most people return to normal daily activities within a few days. For devices with leads, avoid lifting the arm on the implant side above shoulder height and avoid heavy lifting for about four to six weeks, so the leads can settle. Keep the wound clean and dry until it is checked.

Battery life: pacemaker batteries usually last many years — often 7–12 — and ICD batteries somewhat less, depending on how often the device works. Battery level is checked at every follow-up, and replacement is a short, planned procedure.

Everyday life: mobile phones and household appliances are safe; keep phones about 15 cm from the device and use the ear on the other side. Show your device card at airport security. Many modern devices are MRI-conditional — always tell the MRI team you have a device. Ask your cardiologist about driving, especially after an ICD.

Follow-up checklist
✔ Carry your device ID card always
✔ Wound check in about 7–10 days
✔ Device checks as scheduled
✔ Remote monitoring where available
✔ Avoid strong magnets near the device
Call 0422-4042121 or go to the 24/7 Emergency if you faint, have chest pain or breathlessness, notice redness, swelling or discharge at the wound, or receive more than one ICD shock, or a shock and still feel unwell.

What are the risks?

Device implantation is a common, low-risk procedure. Possible complications include bruising or a blood collection at the wound, infection, a lead moving out of position, and, rarely, a collapsed lung or injury to the heart wall. ICDs can occasionally deliver an unnecessary shock, which is usually fixed by reprogramming. Your specialist explains your personal risk beforehand.

Pacemaker & ICD Cost
in Coimbatore

The cost mainly depends on the type of device — single-chamber, dual-chamber, leadless, ICD or CRT — and its features, such as MRI compatibility and remote monitoring. Other factors are the hospital stay and any tests such as an EP study. KG Hospital gives a written estimate once the right device is decided.

KG Hospital is empanelled with 50+ insurers and TPAs and with CMCHIS, PM-JAY, ESI, CGHS and ECHS. Device cover depends on your policy or scheme, so the insurance desk checks eligibility and sends pre-authorisation, usually within 1–4 hours. Call 0422-4042121, Extn 205. Insurance & cashless details →

Coming from another city or country? Our International Patient Care team shares a free estimate within 48 hours of receiving your reports.

Electrophysiology & Device
Specialists at KG Heart Center

KG Heart Center is part of KG Hospital, founded in 1974 by Padma Shri awardee Dr G. Bakthavathsalam, and accredited by NABH.

About this page. Written by the KG Heart Center cardiology and electrophysiology team, KG Hospital, Coimbatore. Clinical information is consistent with the international guidelines listed below. Last updated: .

References

  1. 2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy — European Society of Cardiology.
  2. 2022 ESC Guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death — European Society of Cardiology.

This page is for general information and does not replace advice from your doctor.

Fainting, a Very Slow Pulse or an ICD Shock?

Call immediately — our cardiac team is available 24/7.

FAQs

Pacemaker & ICD Questions

Call our cardiology team at 0422-4042121

A pacemaker treats a heartbeat that is too slow by sending small electrical pulses when needed. An ICD (implantable cardioverter-defibrillator) also watches for dangerous fast rhythms from the lower chambers and stops them with rapid pacing or a shock. Every ICD can also act as a pacemaker.
A pacemaker is usually advised when the heart beats too slowly or pauses and causes symptoms such as dizziness, fainting, tiredness or breathlessness — for example in complete heart block, sick sinus syndrome or atrial fibrillation with a very slow pulse. Tests such as an ECG and Holter monitor confirm the cause.
Pacemaker batteries usually last many years, often about 7–12, depending on how much the device paces. ICD and CRT batteries usually last somewhat less. The battery is checked at every follow-up, and replacement is a short, planned procedure that usually reuses the existing leads.
No. It is a minimally invasive procedure done under local anaesthesia through a small cut below the collarbone, usually taking about 1–2 hours. At KG Hospital most patients go home the same day or the next day.
A leadless pacemaker is a capsule-sized device placed directly inside the heart through a vein in the groin. It has no leads and no pocket under the skin, which lowers the risk of lead and pocket problems. It suits selected patients who need single-chamber pacing, and it is available at KG Hospital.
The cost depends mainly on the device — single-chamber, dual-chamber, leadless, ICD or CRT — and features such as MRI compatibility and remote monitoring, plus the hospital stay. KG Hospital gives a written estimate once the right device is decided, and the insurance desk checks your policy or scheme cover.
Yes. Mobile phones and household appliances are safe; keep the phone about 15 cm from the device and use the ear on the opposite side. At the airport, show your device ID card at security. Avoid leaning over running car engines and strong magnets.
Often yes. Many modern pacemakers and ICDs are MRI-conditional, which means a scan can be done safely under specific conditions after the device is programmed for it. Always tell the doctor and MRI team that you have a device and bring your device card.
An ICD shock feels like a sudden thump or kick in the chest and lasts only a second. If you receive a single shock and feel well afterwards, contact your cardiology team. If you receive more than one shock, or feel unwell after a shock, call 0422-4042121 or go to the emergency department immediately.
Call 0422-4042121 or WhatsApp 96261 96262 to book with the cardiology and electrophysiology team at KG Heart Center, 5, Government Arts College Road, Opposite Court, Gopalapuram, Coimbatore 641018. Bring your ECG, Holter and echo reports and current medicines list.